Before cleaning the Waterpik, make sure the device is turned off and unplugged unless instructed otherwise. To keep the Waterpik clean, wipe it down every week and remember to blow air and water from the irrigator before and after use. Clean the water tank in the dishwasher every one to three months. Disinfect the reservoir, irrigator, attachments, and pen with diluted vinegar or mouthwash. These tips will help you keep your Waterpik clean and in good working order.

Steps

Method 1 of 3: Cleaning the reservoir

  1. 1 Wipe down the device regularly. De-energize the device. Wipe the reservoir with a soft cloth and a mild non-abrasive cleaner. Then rinse the reservoir with clean warm water. If you use the device frequently, then this procedure should be performed weekly.
    • For example, use a damp cloth and a drop of mild liquid soap.
  2. 2 Rinse the reservoir in the dishwasher. Remove the reservoir from the device. If possible, pull out the reservoir valve and set it aside. Place the container, open side down, into the top rack of the dishwasher. Turn on the dishwasher. Dry the reservoir.
    • If you do not know how to remove the reservoir, search the Internet for instructions for your model of device.
    • Stationary models are equipped with a black valve. Do not wash the valve in the dishwasher. Pull it out by pushing the bottom of the valve.
    • Deep clean the reservoir and valve every one to three months.
  3. 3 Flush the valve, if applicable. Rinse the valve under warm running water, kneading it for 30–45 seconds, then set the valve aside. Insert it back into the reservoir by pushing in on all four tabs that are visible under the reservoir.
    • The valve and reservoir must be completely dry and clean before installation.

Method 2 of 3: Cleaning the interior

  1. 1 Purge the irrigator before and after use. Remove the reservoir. Run the irrigator for about ten seconds with the reservoir removed. Turn off the device. Wipe the reservoir well with a paper towel. Position the reservoir at an angle to allow the interior walls of the recess and tubing to dry out.
    • This way, you remove excess air and water, which prevents bacteria and microorganisms from growing.
  2. 2 Run diluted vinegar through the irrigator. Mix 0.5 liters of warm water with 30-60 ml of white vinegar. Pour this solution into the reservoir. Turn on the Waterpik until half of the solution is gone. Turn off the device. Dip the Waterpik into a sink for 20 minutes and let the rest of the solution drain through the handle.
    • Disinfect the device with this solution every one to three months.
    • The vinegar solution removes mineral deposits from hard water.
    • Acetic acid kills bacteria and breaks down fat.
    • Instead of diluted vinegar, you can use a 1: 1 diluted mouthwash with water.
  3. 3 Flush the irrigator. Wash all traces of the vinegar solution from the device. Fill the reservoir with warm water. Run a full tank of warm water through the irrigator and into the sink.
  4. 4 Do not rush to return the reservoir to its place. Place the removed reservoir on a table. Or place it on the device at an angle to leave the internal cavity open. Let the parts dry.
    • Keep the reservoir separate from the device until the next use of Waterpik.

Method 3 of 3: Cleaning the handle and nozzle

  1. 1 Clean the handle. Press the button to remove the irrigator head. Fill a container with white vinegar. Place the irrigator handle in a container. Wait 5-7 minutes and then rinse the pen with warm water.
    • Soak the attachment separately from the handle.
  2. 2 Soak the irrigator head. Press the button to remove the attachment. Fill a container with white vinegar or hydrogen peroxide. Soak the attachment in a container for 5-7 minutes. Rinse the attachment with warm water.
  3. 3 Change the attachment every three to six months. Over time, the nozzle will become clogged with mineral deposits and lose its effectiveness. Additional attachments can be ordered from the Waterpik website.
    • Regular replacement of the nozzle will keep the Waterpik operating efficiently.

Warnings

  • Do not immerse the device in water.
  • Do not use bleach, iodine, baking soda, salt, or concentrated essential oils to clean Waterpik. They can affect the performance of the device and its useful life.
  • Check the instructions for your model or contact your Waterpik representative if you decide to use a different solution (undiluted vinegar or mouthwash) to make sure it is compatible with the device.

What do you need

  • Rag
  • Mild liquid soap
  • Paper towels
  • Dishwasher
  • White vinegar
  • Capacity